Automatic flash point tester of petroleum products
pensky-martens closed cup flash point tester
Automatic flash point tester Pensky-Martens closed cup
Pesky-Martens Closed Cup flash point tester
Product name: Automatic flash point tester of petroleum products
Product Model:FDT-0232
Company:台
Stock:有货
Purchase quantity:
The minimum quantity of an order:1
Buy
Label: ASTM D93 ,flash point tester , ISO 2719
Scope of application
Applied standards: GB/T 261-2008, ASTM D93-02
Application range: applies to the determination of flash point of petroleum products. This product
can measure the flash point of petroleum products in the range of 40-370°Cas required by the standards.
Function characteristics
Features
1, According to GB / T 261-2008 standard for different types of samples A andB two experimental procedures to choose from;
2, Innovation introduced the U.S. imports XECOM data processing chip, fast and accurate processing of the data;
3, Innovative use of the furnace tilting system automatically experiment after the furnace cooling rate faster greatly shorten the time interval between the repeated experiments;
4, The instrument has a self-diagnostic function, automatic prompts to equipment failure;
5,The instrument has self over-temperature protection, over-Measuring range can be arbitrarily set;
6, color liquid crystal display, real-time simulation of real-time trace shows a function of time warming up and test curve, operator interface prompts;
Technical parameters
Specifications
1 Power supply: AC 220V ± 10%, 50Hz
2,Range: room temperature ~ 300 ° C;
3, Repeatability:2 ° C;
4,Reproducibility:4 ° C The visibility: 0.1 ° C;
5, Accuracy: 0.5 ° C;
6, Heating rate: meet GB/T261-2008 standard
7 Ignition way: electronic ignition gas flame
8, Ambient temperature :10-40 ° C;
9, Adapt to the environment humidity: <85%
10 Total power consumption: not more than 300W “
Product name: pensky-martens closed cup flash point tester
Product Model:FDT-0231
Company:set
Stock:有货
Purchase quantity:
The minimum quantity of an order:1
Buy
Label:ASTM D93 ,ISO 2719 closed cup flash point tester,
Scope of application
The instrument is designed and made as per the NationalStandard GB/T261 ASTM D93 ISO 2719 Test Methods for Flash Point and FirePoint of Petroleum Products (Cleveland Open Cup Methods), It is used todetermine flash point of petroleum products and bituminousmaterials, excepting fuel oil and materials having a flashpoint of lower than 79 °C.
Function characteristics
1, with the operating software prompts;
2, with the experimental date, test time parameter prompts;
3, automatic correction of atmospheric pressure and calculated correction values;
4 differential detection, automatic correction system deviation;
5, opening the lid, ignition, detection, print test data computer is done automatically;
6, electronic ignition, the gas flame, forced air cooling.
7, the innovative use of the furnace automatically tilt system, the experiment after the furnace cooling rate faster, greatly shortened several times the time interval between experiments
Technical parameters
1 Power supply: AC
220V ± 10%, 50Hz
2, range: room temperature ~
300 ° C;
3, Repeatability: ≤ 2 ℃
Reproducibility: ≤ 4
° C The visibility: 0.1 ℃
5, Accuracy: 0.5 ℃
6, heating rate:
GB/T261-Standard
7 Ignition way:
electronic ignition gas flame
8, to adapt to
the environment temperature :10-40 ℃
9, adapt to the
environment humidity: <85%
10 Total power
consumption: not more than 300W
Product name: Automatic flash point tester Pensky-Martens closed cup
Product Model:FDT-0272
Company:台
Stock:有货
Purchase quantity:
The minimum quantity of an order:1
Buy
Label:flash point tester,
Scope of application
Applied standards: “”GB/T261-2008ASTM D93 ISO 2719
Application range: applies to the determination of flash point of petroleum products. This productcan
measure The flash point of petroleum products in The range of 40-370°Cas required by The standards.
Function characteristics
1, according to GB / T 261-2008 standard for different types of samples A and B two experimental procedures to choose from;
2, innovation introduced The U.S. imports XECOM data processing chip, fast and accurate processing of The data;
3, innovative use of The furnace tilting system automatically experiment after The furnace cooling rate faster greatly shorten The time interval between The repeated experiments;
4, The instrument has a self-diagnostic function, automatic prompts to equipment failure;
5,The instrument has self over-temperature protection, over-Measuring range can be arbitrarily set;
6, color liquid crystal display, real-time simulation of real-time trace shows a function of time warming up and test curve, operator interface prompts;
Technical parameters
1 Power supply: AC 220V ± 10%, 50Hz
2, Range: room temperature ~ 300 ° C;
3, Repeatability:2 ° C;
4, Reproducibility:4 ° C The visibility: 0.1 ° C;
5, Accuracy: 0.5 ° C;
6, Heating rate: meet GB/T261-2008 standard
7, Ignition way: electronic ignition gas flame
8, Ambient temperature :10-40 ° C;
9, Adapt to The environment humidity: <85%
10 ,Total power consumption: not more than 300W “
Product name: Pesky-Martens Closed Cup flash point tester
Product Model:FDT-0201
Company:set
Stock:in stock
Purchase quantity:
The minimum quantity of an order:1
Buy
Label:GB/T261, Closed Cup, flash point tester,Pesky-Mar
Scope of application
It fully conforms to the GB/T261 ASTM D93 ISO 2719 IP34 Test Methods for closed flash point testerof Petroleum
Products (Penskymartens closed cup Methods), Test Method For flash point determinations of fuels, lubricating oils,
liquids containing suspended solids and liquids that tend to form a surface film during testing. Features and
Benefits Conforms to ASTM D93 and related specifications,Simple automation routine for easy operation
Function characteristics
1. with the operating software prompts;
2.with the experimental date, test time parameter prompts;
3.automatic correction of atmospheric pressure and calculated correction values;
4 .differential detection, automatic correction system deviation;
5.opening the lid, ignition, detection, print test data computer is done automatically;
6.electronic ignition, the gas flame, forced air cooling;
7.the innovative use of the furnace automatically tilt system, the experiment after the furnace cooling rate faster, greatly
shortened several times the time interval between experiments.
Technical parameters
1. Power supply: AC 220V ± 10%, 50Hz;
2. Heating device: heating power continuously adjustable from 0 ~ 600W;